{"id":20,"date":"2015-12-29T15:11:31","date_gmt":"2015-12-29T12:11:31","guid":{"rendered":"http:\/\/ietlinc.com\/?page_id=20"},"modified":"2016-11-03T16:24:00","modified_gmt":"2016-11-03T13:24:00","slug":"services","status":"publish","type":"page","link":"https:\/\/ietlinc.com\/index.php\/services\/","title":{"rendered":"Services"},"content":{"rendered":"<div class=\"vc_row wpb_row vc_row-fluid edgtf-section edgtf-content-aligment-left\" style=\"\"><div class=\"clearfix edgtf-full-section-inner\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"wpb_wrapper\">[rev_slider_vc alias=&#8221;services&#8221;]<div class=\"vc_empty_space\"  style=\"height: 32px\" ><span class=\"vc_empty_space_inner\"><\/span><\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid edgtf-section edgtf-content-aligment-left edgtf-grid-section\" style=\"\"><div class=\"clearfix edgtf-section-inner\"><div class=\"edgtf-section-inner-margin clearfix\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>OUR SERVICES<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Our air quality testing services include but not limited to the following:<br \/>\nAmbient air quality continuous monitoring for pollutant gases (SO2, NO, NO2, NOx, CO, THC, NMHC, CH4, O3, NH3, H2S, CO2, HF and BTEX) and particulate matter (PM10, PM2.5 and PM1) Fig. 1.<\/p>\n<ul>\n<li>Continuous monitoring for weather metrological parameters (Wind speed, wind direction, humidity, temperature and precipitation).<\/li>\n<\/ul>\n<ul>\n<li>Particulate matter non-continuous monitoring (PM2.5, PM10, TSP) using high volume samplers (HVS). Filters can be sent to laboratory for further analysis including metals and hydrocarbons.<\/li>\n<\/ul>\n<ul>\n<li>Air quality assessment and consulting.<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper vc_box_shadow_border  vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"545\" height=\"545\" src=\"https:\/\/ietlinc.com\/wp-content\/uploads\/2015\/12\/services3.jpg\" class=\"vc_single_image-img attachment-full\" alt=\"\" srcset=\"https:\/\/ietlinc.com\/wp-content\/uploads\/2015\/12\/services3.jpg 545w, https:\/\/ietlinc.com\/wp-content\/uploads\/2015\/12\/services3-150x150.jpg 150w, https:\/\/ietlinc.com\/wp-content\/uploads\/2015\/12\/services3-300x300.jpg 300w\" sizes=\"auto, (max-width: 545px) 100vw, 545px\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid edgtf-section edgtf-content-aligment-left\" style=\"\"><div class=\"clearfix edgtf-full-section-inner\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"wpb_wrapper\"><div class=\"vc_empty_space\"  style=\"height: 50px\" ><span class=\"vc_empty_space_inner\"><\/span><\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid edgtf-section edgtf-content-aligment-left edgtf-grid-section\" style=\"\"><div class=\"clearfix edgtf-section-inner\"><div class=\"edgtf-section-inner-margin clearfix\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>EQUIPMENT<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n<div class=\"vc_empty_space\"  style=\"height: 32px\" ><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Below is list of all our Ambient Air Quality Equipments:<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"86\"><strong>Instrument<\/strong><\/td>\n<td width=\"51\"><strong>Measure<\/strong><\/p>\n<p><strong>Pollutant<\/strong><\/td>\n<td width=\"70\"><strong>Detection<\/strong><\/p>\n<p><strong>Method<\/strong><\/td>\n<td width=\"43\"><strong>Detect.<\/strong><\/p>\n<p><strong>Limit<\/strong><\/td>\n<td width=\"41\"><strong>Range<\/strong><\/td>\n<td width=\"38\"><strong>Unit<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"86\">Horiba \u2013APSA370<\/td>\n<td width=\"51\">SO<sub>2<\/sub><\/td>\n<td width=\"70\">UV fluorescence<\/td>\n<td width=\"43\">0.0005<\/td>\n<td width=\"41\">0 &#8211; 0.5<\/td>\n<td width=\"38\">ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">Horiba \u2013APNA370<\/td>\n<td width=\"51\">NOx<\/td>\n<td width=\"70\">chemiluminescence<\/td>\n<td width=\"43\">0.0005<\/td>\n<td width=\"41\">0 \u2013 1<\/td>\n<td width=\"38\">ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">Horiba \u2013APMA370<\/td>\n<td width=\"51\">CO<\/td>\n<td width=\"70\">non-dispersive IR<\/td>\n<td width=\"43\">0.05<\/td>\n<td width=\"41\">0 &#8211; 100<\/td>\n<td width=\"38\">ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">Horiba \u2013APHA370<\/td>\n<td width=\"51\">THC<\/p>\n<p>NMHC<\/p>\n<p>CH<sub>4<\/sub><\/td>\n<td width=\"70\">FID<\/td>\n<td width=\"43\">0.05<\/td>\n<td width=\"41\">0 &#8211; 50<\/td>\n<td width=\"38\">ppmC<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">Horiba \u2013APOA370<\/td>\n<td width=\"51\">O<sub>3<\/sub><\/td>\n<td width=\"70\">non dispersive UV<\/td>\n<td width=\"43\">0.0005<\/td>\n<td width=\"41\">0 \u2013 1<\/td>\n<td width=\"38\">ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">Horiba \u2013APNA370<\/td>\n<td width=\"51\">NH<sub>3<\/sub><\/td>\n<td width=\"70\">chemiluminescence<\/td>\n<td width=\"43\">0.0005<\/td>\n<td width=\"41\">0 \u2013 1<\/td>\n<td width=\"38\">ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">Horiba \u2013APSA370<\/td>\n<td width=\"51\">H<sub>2<\/sub>S<\/td>\n<td width=\"70\">UV fluorescence<\/td>\n<td width=\"43\">0.0005<\/td>\n<td width=\"41\">0 &#8211; 0.5<\/td>\n<td width=\"38\">ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">Horiba-VA-3001<\/td>\n<td width=\"51\">CO<sub>2<\/sub><\/td>\n<td width=\"70\">non-dispersive IR<\/td>\n<td width=\"43\">&#8211;<\/td>\n<td width=\"41\">0 &#8211; 100<\/td>\n<td width=\"38\">ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">Gimm-180<\/td>\n<td width=\"51\">PM<sub>10<\/sub> PM<sub>2.5<\/sub><\/p>\n<p>PM<sub>1<\/sub><\/td>\n<td width=\"70\">light-scattering<\/td>\n<td width=\"43\">NA<\/td>\n<td width=\"41\">0.1-10,000<\/td>\n<td width=\"38\">ug\/m<sup>3<\/sup><\/td>\n<\/tr>\n<tr>\n<td width=\"86\">Honeywell-SPM<\/td>\n<td width=\"51\">HF<\/td>\n<td width=\"70\">Chem-cassette<\/td>\n<td width=\"43\">50<\/td>\n<td width=\"41\">0-2000<\/td>\n<td width=\"38\">ppb<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">Syntech Spectras Analyzer GC955<\/td>\n<td width=\"51\">BTEX<\/td>\n<td width=\"70\">PID<\/td>\n<td width=\"43\">0.15<\/td>\n<td width=\"41\">0 \u2013 300<\/td>\n<td width=\"38\">ppb<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">SIBATA-High Volume Samplers, Fig.2<\/td>\n<td width=\"51\">PM<sub>10<\/sub> PM<sub>2.5<\/sub><\/p>\n<p>TSP<\/td>\n<td width=\"70\">Gravity<\/td>\n<td width=\"43\">NA<\/td>\n<td width=\"41\">&#8211;<\/td>\n<td width=\"38\">ug\/m<sup>3<\/sup><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\t\t<\/div>\n\t<\/div>\n<div class=\"vc_empty_space\"  style=\"height: 50px\" ><span class=\"vc_empty_space_inner\"><\/span><\/div>\n<\/div><\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid edgtf-section edgtf-content-aligment-center\" style=\"\"><div class=\"clearfix edgtf-full-section-inner\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"wpb_wrapper\"><a href=\"\/index.php\/contact\" target=\"_self\" style=\"font-size: 24px;font-weight: 300;margin: 30px\" class=\"edgtf-btn edgtf-btn-large edgtf-btn-outline edgtf-btn-icon\"  >\n    <span class=\"edgtf-btn-text\">GET IN TOUCH TODAY<\/span>\n    <i class=\"edgtf-icon-font-awesome fa fa-envelope-o edgtf-btn-icon-element\" ><\/i><\/a><div class=\"vc_empty_space\"  style=\"height: 32px\" ><span class=\"vc_empty_space_inner\"><\/span><\/div>\n<\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"[rev_slider_vc alias=\"services\"] OUR SERVICES Our air quality testing services include but not limited to the following: Ambient air quality continuous monitoring for pollutant gases (SO2, NO, NO2, NOx, CO, THC, NMHC, CH4, O3, NH3, H2S, CO2, HF and BTEX) and particulate matter (PM10, PM2.5 and [...]","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"full-width.php","meta":{"footnotes":""},"class_list":["post-20","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/ietlinc.com\/index.php\/wp-json\/wp\/v2\/pages\/20","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ietlinc.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ietlinc.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ietlinc.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ietlinc.com\/index.php\/wp-json\/wp\/v2\/comments?post=20"}],"version-history":[{"count":12,"href":"https:\/\/ietlinc.com\/index.php\/wp-json\/wp\/v2\/pages\/20\/revisions"}],"predecessor-version":[{"id":433,"href":"https:\/\/ietlinc.com\/index.php\/wp-json\/wp\/v2\/pages\/20\/revisions\/433"}],"wp:attachment":[{"href":"https:\/\/ietlinc.com\/index.php\/wp-json\/wp\/v2\/media?parent=20"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}